首頁 > 產品資訊 > 直流電源供應器 (New!) > TPS SERIES 交換式直流電源供應器

Switching Mode Power Supply
交換式直流電源供應器

TPS SERIES 交換式直流電源供應器
TPS SERIES

CE, Remote Control, Output ON/OFF, USB

Features:

  • Rotary Encoder Control Knob with coarse & fine tuning
  • 3 user defined V & I presets (recalls)
  • Full remote Control of V, I and output on-off
  • High RFI immunity & excellent EMI
  • Isolated ground, Active PFC & high power efficiency
  • Intelligent fan control from zero to full speed
  • Remote Sensing
  • Overload, Over Temperature & Tracking Over Voltage protections
  • Optional programamble features:
  • - USB inteface for remote programamble control via computer
    - 20 programamble sets of V&I presets with different time duration and uo to 999 cycles
功能特點:
  • 使用飛梭旋鈕,可輕易控制粗調及微調。
  • 內建3組電壓,電流儲存及呼叫功能。
  • 遠端控制功能:可控制電壓,電流及輸出ON/OFF。
  • 具有高度抗輻射及電磁波幹擾。
  • 智慧型風扇控制。
  • 過載保護,過溫保護及追蹤過電壓保護功能。
  • 全新的設計體積小,重量輕。
  • 選配可程式功能:
  • - USB介面,可通過電腦進行可程式遠端控制。
    - 內建20組可程式電壓、電流設定存儲及呼叫,可設定不同時間段,最高可運行999個週期。
MODEL
TPS-1560: 1~15V, 0~60A
TPS-3030: 1~30V, 0~30A
TPS-6015: 1~60V, 0~15A
TPS-1530: 1~15V, 0~30A
TPS-3015: 1~30V, 0~15A
TPS-6008: 1~60V, 0~8A
TPS-3020: 1~30V, 0~20A
TPS-6010: 1~60V, 0~10A
Specifications:
Model TPS-1560 TPS-3030 TPS-6015
Output voltage 1~15VDC 1~30VDC 1~60VDC
Output current 0~60A 0~30A 0~15A
Voltage Regulation
Load (10~100% load) 50mV
Line (170~264VAC variation) 20mV
Current Regulation
Load 200mA 150mA 100mA
Line (170~264VAC variation) 50mA
Ripple & Noise
Ripple & Noise (r.m.s) voltage 5mV
Ripple & Noise (peak-peak) voltage 50mV 50mV 100mV
Switching Frequency 65-85KHz~ 75-95KHz~ 68-85KHz~
Tracking Over Voltage Protections O/P 1~5V: set voltage +2V
O/P 5~15V: set voltage +3V
O/P 1~5V: set voltage +2V
O/P 5~20V: set voltage +3V
O/P 20~30V: set voltage +4V
O/P 1~5V: set voltage +2V
O/P 5~20V: set voltage +3V
O/P 20~60V: set voltage +4V
Meter Type & Accuracy
Voltage Meter 3 Digit LED Display ±0.2% + 3counts
Current Meter 3 Digit LED Display ±0.2% + 3counts
Display resolution Voltmeter: 100mV Ammeter: 10mA
Input Voltage 1000~120VAC, or 200~240VAC 50/60Hz~
Full Load Input Current 4.7A 4.5A 4.5A
Efficiency 85% 86% 88%
Power Factor Control Power factor correction >0.95 at optimal load
Cooling Method Thermostatic Control Fan from Zero to full speed
Protections Overload, Short Circuit by Constant Current, Output Tracking Over Voltage, Over Temperature
Special Features 3 User defined V & I preset, Remote control V, I and output on-off
Remote Sensing (only for TPS-1560)
Optional programmable features
Interface USB
Preset cycle programmming Max.20 psets of V&I
Max.preset time: 100 minutes (99min.+60sec.)]
Max.preset cycle: 999
Dimensions 200Wx90Hx275D mm
Weight 3.2kg

All values are based on the Standard ambient Temperature 25 ℃ and Pressure 0.1Mpa.
Specifications are subject to change without prior notice.


Specifications:
Model TPS-1530 TPS-3015 TPS-6008 TPS-3020 TPS-6010
Output voltage 1~15VDC 1~30VDC 1~60VDC 1~30VDC 1~60VDC
Output current 0~30A 0~15A 0~8A 0~20A 0~10A
Voltage Regulation
Load (10~100% load) 50mV
Line (170~264VAC variation) 20mV
Current Regulation
Load 150mA 100mA 100mA 100mA 100mA
Line (170~264VAC variation) 50mA
Ripple & Noise
Ripple & Noise (r.m.s) voltage 5mV
Ripple & Noise (peak-peak) voltage 50mV 50mV 10mV 50mV 100mV
Switching Frequency 65-85kHz~ 75-95kHz~ 65-85kHz~ 75-95KHz~ 68-85KHz~
Tracking Over Voltage Protections O/P 1~5V: set voltage +2V
O/P 5~15V: set voltage +3V
O/P 1~5V: set voltage +2V
O/P 5~20V: set voltage +3V
O/P 20~30V: set voltage +4V
O/P 1~5V: set voltage +2V
O/P 5~20V: set voltage +3V
O/P 20~60V: set voltage +4V
O/P 1~5V: set voltage +2V
O/P 5~20V: set voltage +3V
O/P 20~30V: set voltage +4V
O/P 1~5V: set voltage +2V
O/P 5~20V: set voltage +3V
O/P 20~60V: set voltage +4V
Meter Type & Accuracy
Voltage Meter 3 Digit LED Display ±0.2% + 3counts
Current Meter 3 Digit LED Display ±0.2% + 3counts
Display resolution Voltmeter: 100mV Ammeter: 10mA
Input Voltage 1000~120VAC, or 200~240VAC 50/60Hz~
Full Load Input Current 2.4A 2.4A 2.4A 3.1A 3.1A
Efficiency 85% 85% 88% 87% 89%
Power Factor Control Power factor correction >0.95 at optimal load Power factor correction >0.9 at optimal load
Cooling Method Thermostatic Control Fan from Zero to full speed
Protections Overload, Short Circuit by Constant Current, Output Tracking Over Voltage, Over Temperature
Special Features 3 User defined V & I preset, Remote control V, I and output on-off
Optional programmable features
Interface USB
Preset cycle programming Max.20 psets of V&I
Max.preset time: 100 minutes (99min.+60sec.)]
Max.preset cycle: 999
Dimensions 200Wx90Hx215D mm
Weight 2.6kg

All values are based on the Standard ambient Temperature 25 ℃ and Pressure 0.1Mpa.
Specifications are subject to change without prior notice.